THE FORMATION INSTRUCTION OF DIESEL GENERATING SETS
1. Diesel generating sets
Diesel generating sets include diesel engine, alternator and control box and all the alternators.
2. Stating method of gen-sets.
a). manual switcher
b). automatic starting wholly: when electric supply has been stopped, the gen-sets can start three times automatically in 3-28 seconds (time can be adjustable) between electric supply and gen-sets need 6-8 seconds. It will spend 12 seconds to accept load when electric supply resumed, gen-set will maintain 23-230 seconds, then closes down automatically.
3.Control system
Apparatus: voltmeter, frequency meter, amperage meter, voltmeter of battery, meter of water temp, oil meter . control section: starting handler, key type switch, inductive type self-protection switch, and indicator.
Other Main Performance
1. Voltage stead-state regulation ±1% fluctuation 1.5% Transient-stater egulation -15~20% stead time 5s
Frequency Stead-state regulation 5% fluctuation ratio 1.5% Transient-state regulation ±10% stead time 5s
2. The noise of gen-sets should no more than 85db(a) The fuel consumption in no more than 2.5kg/kw.h.